© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 12/19/13
Axial Lead & Cartridge Fuses
5×20 mm > Medium-Acting > 232 Series
232 Series, 5×20 mm, Medium-Acting Fuse
Agency Approvals
Agency Agency File Number Ampere Range
PS
E
Cartridge Certificates:
NBK260202-E10480 B
NBK290502-E10480 D
Leaded Certificates:
NBK290502-E10480 B
NBK290502-E10480 F
1A – 5A
6.3A – 10A
1A – 5A
6.3A – 10A
Certificates:
SU05001-2015
1A – 10A
1A – 10A
Features
Electrical Characteristics for Series
• DesignedtoJapanese
Standard JIS C6575
• Availableincartridgeand
axial lead format
• RoHScompliantand
lead-free
% of Ampere
Rating
Opening Time
130% 1 hour, Minimum
160% 1 hour, Maximum
200% 2 minutes, Maximum
Applications
Electrical Characteristic Specifications by Item
Amp Code
Amp Rating
(A)
Voltage
Rating
(V)
Interrupting
Rating
Nominal Cold
Resistance
(Ohms)
Nominal
Melting
I
2
t
(A
2
sec)
Agency Approvals
PS
E
0 01. 1 125/250
10,000A @ 125VAC
0.0923 1.37300 x x x
1.25 1.25 125/250 0.0685 4.11000 x x x
01. 6 1. 6 125/250 0.0537 6.96000 x x x
002. 2 125/250 0.0370 8.25000 x x x
02.5 2.5 125/250 0.0291 13.87500 x x x
003. 3 125/250 0.0226 17.19000 x x x
3.15 3.15 125/250 0.0215 21.9500 x x x
004. 4 125/250 0.0174 37.73000 x x x
005. 5 125/250 0.0134 56.72000 x x x
06.3 6.3 125/250
300A @ 125VAC
0.0102 90.41500 x x x
008.* 8 125/250 0.0076 182.58000 x x x
010.* 10 125/250 0.0059 290.66500 x x x
5×20mm medium–acting glass body cartridge fuse
designed to Meti B Standard.
Used as supplementary protection in appliance or
utilization equipment to provide individual protection for
components or internal circuits.
PS
E
Description
To order 125Vac rated, please add part no. suffix
* Interrupting Rating for 8A & 10A is 100A@250Vac
Additional Information
Datasheet
Samples
Resources
Komentáře k této Příručce